Soft dB Opus Suite Building Acoustics Module Airborne Sound Isolation between Rooms ASTM E 336_ISO 140-4 User Manual

Page 18

Advertising
background image

17

If an element of the table is selected, the measurement interface will

be called (see the following subsections).

Click this button to delete the selected table element.

The import feature allows the user to load one column of data (one of

the 4 data types) from another partition of the same file. It is then

possible to avoid repeating the same measurements when several

partitions share data with each other.

Table of Measurements

The measurement table contains four columns for the four types of measurement:

• Source room, level measurement, source on

• Receiving room, level measurement, source on

• Receiving room, level measurement, source off

• Receiving room, reverberation time measurement

Several measurements can be done for each of the four types. To add a new element in the table,

simply press on “new…” in the proper column. The average value of those measurements will later

be used in the STC evaluation. To see the average from the measurement tab, click on the header

element above the first measurement element of a column.

Source room

Level measure

Source on

Receiving room

Level measure

Source on

Receiving room

Level measure

Source off

Receiving room

Reverberation

Advertising