4 Quick Start

The STC module is part of the Building Acoustic. It can be accessed in the Building Acoustic menu of

the Opus Suite panel.

Measurement tab

What you should know…

• The partition area and the receiving room volume are used to evaluate de STC.

• You need at least 4 measurements: level in the source room (source on), level in the

receiving room (source on), background level in the receiving room (source off) and

reverberation time in the receiving room.

• The main interface let do an unlimited quantity of measurements for every type of data.

• Select the corresponding column header to see the average of the different measurements

of a type of data.

• The selected element of the table shows a green background. The details of the selection

are displayed on the right side of the table.

• The elements still to measure display a question mark (?) as a value and have a yellow

background.

Elements to

measure

Measure the

selected element