Veris Technologies MSP EC and pH (1997-2008 floppy disk drive 1.02E) - Operating Instructions User Manual

Page 28

Advertising
background image

Veris Technologies

Pub. #OM MSP03-1

28

Field Operations

Tools required for Field Operation adjustments
-3/16” allen wrench
-adjustable wrench: min. 10” (25 cm) length
-3/4” socket and wrench
-9/16” socket or wrench
-15/16” wrench

Starting Engine
Turn fuel valve to On position by sliding it to the far right. Move the choke lever to the far left Closed
position, if engine is cold. Slide the throttle lever slightly to the left. Turn the engine switch to the on
position. Turn key on. As engine warms up, gradually move choke lever to the far right Open
position. Position the throttle lever to maximum engine RPM.



• Pinch point hazard: to prevent injury, stand clear when raising or lowering any part of the Veris
MSP. Disengage automatic cycling function before working around unit. Install all transport locks
before transporting or working underneath.

Manually Operating Wash and Cycling Functions
1. After all cables and hydraulic hoses are connected, start engine and test unit by raising and

lowering MSP unit using external or cab Raise/Lower switch. Make sure no one is under unit and
keep clear of any pinch points.

throttle


choke


fuel valve


ignition key

external
Raise/Lower
switch

cab

Raise/Lower

switch

Advertising