VEGA Visual Operating

Set-up of a VBUS-radar sensor VEGAPULS 81F

The echo curve shows all reflec-
tions of the radar signal, i.e. not only
the product echo but also the false
echo. When you click with the cur-
sor, here having a different form
(

á), to a "top“ of the curve, you see

in the text field the distance of the
echo from the sensor (in m), the
amplitude (in dB) and a probability
value (in %), whether the top is the
true product echo.

Click to

Zoom, when you want to

increase a part of the echo curve in
size. The cursor then takes the form
of a broken vertical line. Move this
line with pushed mouse key above
the sector you want to increase in
size. Click to

Unzoom to return to

the original size.