Set-up of a signal conditioning instrument VEGAMET 614

For processing of linearisation curves,
click to

Instrument data, then to Lineari-

sation curves.

Choose the curve you want to process
and click to

Edit.

Here you can generate a linearisa-
tion curve with max. 32 value pairs.
Enter the value pairs in the appro-
priate fields "Percentage value“ and
"Linearised“ and click then to Pair of
measured values

Transfer. If you

want to remove a value pair, you can
click to the pair either in the curve or
in the table and then click to

Delete.

By clicking twice to

OK, you return

to the window "Conditioning“.

When you click to

Calculate, the

Help program starts "Tank Calcula-
tion“. There you can calculate the

linearisation curves by means of vessel
forms and dimensions (see chapter "4 Tank
calculation“).