VEGA VVO VEGA Visual Operating User Manual
Page 42
Advertising
![background image](/manuals/260752/42/background.png)
42
VEGA Visual Operating
Establishing of a linked measurement loop with VEGAMET 515V
In the window "Modify sensor coordination“
you are informed that two measurement
loops are concerned by this modification (as
this is a linked application). Click to
Yes.
Choose in the window "Sensor coordination“
the input or the serial number (if not already
chosen) and click to
Input.
In this window "Input configuration" you first of
all mark
additional functions. Then choose
VEGAMET number 5 (DISBUS-address of
the other VEGAMET). Then choose the input
of the other VEGAMET. Click to
OK.
Now you see that sensor A of your
measurement loop is a sensor which is
connected to VEGAMET 5 (to input 2).
Click to
OK to terminate the procedure.