If the motion sensor is triggered by a short vibration pulse in static state, you

may configure the device to watch for further vibration before switching to

moving state. An intermediate state called validation state is used to confirm the

movement. If the moving distance exceeds the threshold (R9) within allowable

time window (RD), the device will switch to moving state. Otherwise it will return

to static state. Validation state can be disabled by setting R9=0.

Traveled distance can be used as a motion syndrome in moving state. If the

traveled distance exceeds the threshold (RE) within specified time (RF), the

device will keep in moving state. Setting RE=0 will disable the distance check.

You may configure parameters to send report by specific media for state

transition.

If report interval is set to 0, TR-206 will not send report in respective state.

Parameter ‘O1’ is used to control the sensitivity of motion sensor. The larger the

value is, the less sensitive the sensor is.

The related parameters are listed below.

Code

word

Parameters

Value

Description

R0

Report interval in static state

1~4 Giga

seconds

R1

Report interval in moving state

1~4 Giga

seconds

R2

Report Media

Media type

Please refer to 2.9

Report media

R3

Traveled distance for sending

report

0=disable

1~4Giga

Unit: meter

If you want TR-206 to

send reports

according to traveled

distance, you have to

extra make GPS on.

Please refer to

“Chapter 4 GPS.”

R7

Automatic change from

1/0

0=disable