2 speed limits, High speed limit, Low speed limit – GLOBALSAT TR-206 User Manual

Page 53

Advertising
background image

52

7.2 Speed Limits

TR-206 implements high speed alarm and low speed alarm. There’re two

parameters for the function to work. One is the speed limit (OI / OJ). The other

one is the hysteresis range (OP). Once the speed alarm is detected, the alarm

flag of alarm status is set and a report is sent. The alarm flag will be

automatically dismissed if the alarm condition is disappeared. Speed alarm

detection requires GPS information so the GPS should be turned on. Please

refer to chapter “5. GPS” for the setting. Please refer to the illustrations below

for the detection behavior.

High Speed Limit











Low Speed Limit










OI

OP

OP

OI+

OP

OI-

OP

OJ

OP

OP

OJ+

OP

OJ-

OP

Keep sending alarm

Alarm

Speed lower than the bottom limit

Speed higher than the top limit

Automatic dismiss alarm

Alarm

Speed higher than the top limit

Keep sending alarm

Speed lower than the bottom limit

Automatic dismiss alarm

n

o

p

q

n

o

p

q