13 Data Log

The function of Data Log is used to record the GPS location information in TR-206.

The recording criteria may based on time interval or/and traveled distance. If

traveled distance criterion is selected, GPS must be turned on to calculate the

moving distance. If both criteria are applied, then the device will save one record if

any one of the criteria is matched and resets the counting.

If you want TR-206 to store position according to traveled distance,

you have to extra make GPS on. Please refer to “Chapter 5 GPS.”

The recorded information can be uploaded to PC by USB interface or be

transmitted to server by GPRS remotely.

To enable data log function, you should configure parameters ‘O2’ & ‘OH’ and send

‘N8’ command. Command ‘N9’ is used to disable the function. The related

parameters are listed below.

Codeword

Parameters

Value

Description

O2

Data logger interval

u16, in seconds

0 ~ 65535

0=disable

OH

Data logger distance

u32, in meters

0 ~ 4 Giga

0=disable

Command Codeword

Parameters

N8

Enable Data logger

N9

Disable data logger

Example 1:

Enable data log function with 10 seconds interval.

GSC,123456789012345,N8(O2=10)*51!

Example 2:

Enable data log function with 2 minutes interval, maximum distance=100m & GPS

always on.

GSC, 123456789012345,N8(O2=120,OH=100,C0=1)*37!