2.

cut out the supplied template (see

Figure 46) and align the template

onto the rear of the IP, squarely

seating it on the top of the IP

mounting pin (see Figure 47).

3.

Using a

3

8

” Uni-bit, center the

bit onto the

3

8

” drill location on the

template and slowly drill through the

IP. Using a

1

8

” drill bit, center and

drill through the

1

8

” location on the

template. Remove and discard the

template and any plastic shavings.

4.

On the front side of the IP, align

the Power Level Selector Switch label

onto the previously drilled hole (see

Figure 48).

Figure 47