4. Installation

PNEG-012 Vane Axial Heater

15

Bin Configuration

Figure 4E

IMPORTANT: When mounting two (2) heaters on a bin it is imperative that they be situated as shown in

Figure 4E

. Plenum thermostat must be to the right of master heater and master heater must

be to the right of slave heater.

Transition High-Limit Installation

1. Mark location on transition one foot up from the bottom (entrance collar) and centered in

the transition.

2. Drill or knock out 7/8" diameter hole on marked location.

3. Install transition high-limit using supplied self-drilling screws.

Figure 4F The transition connecting the Vane Axial Heater to the bin with the plenum sensor in place.