Plenum thermostat mounting – Grain Systems PNEG-012 User Manual

Page 16

Advertising
background image

4. Installation

16

PNEG-012 Vane Axial Heater

Plenum Thermostat Mounting

The plenum thermostat must be ordered separately from the heater unit.

1. Follow installation instructions provided with the thermostat assembly.

2. Position the housing so that the bolt flanges are vertical, and the cord exits the housing from the

bottom. Mark position.

3. Use 6 (4.00") or 8 (2.66") self-drilling screws to mount the housing to the bin sidewall. DO NOT

TIGHTEN COMPLETELY. Insert corrugation seal into gap between housing and sidewall.
Tighten screws.

4. Caulk between the housing and the sidewall to seal.

Figure 4G Plenum thermostat mounted on bin wall.

IMPORTANT: Thermostat must be installed for safe operation.

Figure 4H Side view of thermostat showing corrugation seal.

Advertising