Heater orifice setup, Installation – Grain Systems PNEG-012 User Manual

Page 17

Advertising
background image

4. Installation

PNEG-012 Vane Axial Heater

17

Heater Orifice Setup

The factory has set the orifices size for propane, high temperature and natural gas, low temperature.

1. Determine the type of gas to be used: Propane or natural gas.

2. Determine the operating temperature ranges to be used: High or low. Refer to tables on

Page 23

and

Page 24

.

3. For natural gas high temperature applications remove reducer bushing with pressure gauge and

remove 7/32" primary orifice from system. Replace reducer bushing and check connections for leaks.
For natural gas high temperature configuration there is no primary orifice in the system. Refer to

Fuel - Temperature Table below

.

4. For propane low temperature applications remove reducer bushing with pressure gauge and replace

the supplied 7/32" primary orifice with a 3/32" orifice supplied in control box. Replace reducer
bushing and check connections for leaks. Refer to

Fuel - Temperature Table below

.

Figure 4I

Fuel - Temperature

Fuel

Temperature

High

Low

Natural Gas

Remove primary orifice completely.

No modifications required.
Standard with 7/32" orifice.

Propane

No modifications required.
Standard with 7/32" orifice.

Replace primary orifice with 3/32"
orifice supplied in control box.

CAUTION

Make sure the configuration matches the appropriate application in the

Fuel - Temperature Table above.

Propane has a higher BTU content than natural

gas. Do not remove 3/8" secondary orifice. Excessive heat rise due to improper
orifice sizing or removing the 3/8" secondary orifice will damage grain or
cause fire.

Advertising