Operation – Grain Systems PNEG-012 User Manual

Page 23

Advertising
background image

5. Operation

PNEG-012 Vane Axial Heater

23

BTUs per Gauge Pressure (PSI) - Propane Models (Approximate)

High Temperature

Low Temperature

Gauge Pressure (PSI) Required to Maintain Temperatures (Approximate)

(Shaded Areas Represent Low Temperature Settings)

Diameter

Operating Pressure (PSI)

2

4

6

8

10

12

14

16

18

20

24", 26" and 28"

892,353

1,218,775 1,496,555 1,734,425 1,940,412 2,121,835 2,285,304 2,436,723 2,581,288 2,723,487

Diameter

Operating Pressure (PSI)

2

4

6

8

10

12

14

16

18

20

All Models

163,902

223,857

274,877

318,568

356,402

389,725

419,750

447,561

474,114

500,232

Fan

Model

Static

Pressure

Heat Rise °F

60

80

100

120

140

160

180

3 HP-18"

1"

10

2

3

4

5

7

8

2"

6

10

2

2

3

4

5

3"

2

3

5

6

8

10

14

5 HP-24"

1"

10

1

1

1

2

2

3

2"

6

10

14

1

1

1

2

3"

2

3

4

6

8

10

14

7 HP-24"

1"

2

3

4

5

7

9

12

2"

2

2

3

4

5

6

8

3"

1

1

2

3

3

4

5

4"

5

9

14

20

1

1

2

10 HP-24"

1"

2

3

5

6

8

12

14

2"

2

3

4

5

7

9

12

3"

1

2

3

4

5

6

7

4"

12

20

1

1

2

3

3

5"

4

7

12

15

20

1

1

15 HP-26"

1"

3

4

6

9

12

14

20

2"

2

3

5

7

10

12

16

3"

2

3

4

5

7

9

12

4"

1

2

3

3

5

6

7

5"

14

1

1

2

2

3

4

15 HP-28"

1"

4

7

10

14

20

25

30

2"

3

6

8

12

16

20

25

3"

3

5

7

10

14

18

20

4"

2

4

5

8

10

14

16

5"

2

3

4

5

7

9

12

Advertising