20

SERIES 2000 DRYER CONTROL PANEL

SERIES 2000 DRYER CONTROL PANEL

SERIES 2000 DRYER CONTROL PANEL

SERIES 2000 DRYER CONTROL PANEL

SERIES 2000 DRYER CONTROL PANEL

Figure 5: The Competitor Series 2000 Control System

Figure 5: The Competitor Series 2000 Control System

Figure 5: The Competitor Series 2000 Control System

Figure 5: The Competitor Series 2000 Control System

Figure 5: The Competitor Series 2000 Control System

the dryer is restarted the timers will
continue timing down. The timers
will return to their initial settings by
pressing and holding the STOP
button for 5 seconds.

automatically entered.

3. Keep pressing the PROGRAM

(DELAYS) button until the car-
rot disappears or press the MODE
SELECT button once to exit.

SETTING THE LOAD AND

SETTING THE LOAD AND

SETTING THE LOAD AND

SETTING THE LOAD AND

SETTING THE LOAD AND

UNLOAD DELAYS

UNLOAD DELAYS

UNLOAD DELAYS

UNLOAD DELAYS

UNLOAD DELAYS

1. Press the PROGRAM (TEM-

PERATURES) button until the
carrot is under the temperature
setting to be changed.

2. Use the UPand DOWN arrow

keys to change the present tem-
perature to the new one. The
new time is automatically entered.

3. Keep pressing the PROGRAM

(TEMPERATURES) button until
the carrot disappears or press the
MODE SELECT button once to exit.

CHECKING THE HOUR

CHECKING THE HOUR

CHECKING THE HOUR

CHECKING THE HOUR

CHECKING THE HOUR

METER

METER

METER

METER

METER

MONITORING GRAIN

MONITORING GRAIN

MONITORING GRAIN

MONITORING GRAIN

MONITORING GRAIN

TEMPERATURES, PLENUM

TEMPERATURES, PLENUM

TEMPERATURES, PLENUM

TEMPERATURES, PLENUM

TEMPERATURES, PLENUM

TEMPERATURE OR TIMERS

TEMPERATURE OR TIMERS

TEMPERATURE OR TIMERS

TEMPERATURE OR TIMERS

TEMPERATURE OR TIMERS

DRYER SAFETY CIRCUIT

DRYER SAFETY CIRCUIT

DRYER SAFETY CIRCUIT

DRYER SAFETY CIRCUIT

DRYER SAFETY CIRCUIT

The LOAD DELAY is used to delay the
starting of the load auger

load auger

load auger

load auger

load auger when the

dryer is unloading to prevent the load

load

load

load

load

auger

auger

auger

auger

auger from starting and stopping too
often. The UNLOAD DELAY is used to
control the amount of time the unload

unload

unload

unload

unload

auger

auger

auger

auger

auger runs after the metering rolls

metering rolls

metering rolls

metering rolls

metering rolls

stop to allow for auger cleanout.

1. Press the PROGRAM (DELAYS)

button until the carrot is under the
time delay to be changed.

2. Use the UP and DOWN arrow

keys to change the present time
to the new one. The new time is

SETTING THE MOISTURE

SETTING THE MOISTURE

SETTING THE MOISTURE

SETTING THE MOISTURE

SETTING THE MOISTURE

CONTROL AND PLENUM

CONTROL AND PLENUM

CONTROL AND PLENUM

CONTROL AND PLENUM

CONTROL AND PLENUM

SET POINT

SET POINT

SET POINT

SET POINT

SET POINT

Press the UP arrow key and the total
hours on the machine are displayed.

Use the mode select to decide which
of the modes you want to view.

The Competitor Series 2000 Con-

Competitor Series 2000 Con-

Competitor Series 2000 Con-

Competitor Series 2000 Con-

Competitor Series 2000 Con-

trol System

trol System

trol System

trol System

trol System continuously checks all
safety circuits on the dryer, and will
automatically shut the dryer down
should a problem occur. The cause
of the dryer shutdown will be shown
on the LCD display. To restart the
dryer after a safety shutdown, first
correct the reason for the shutdown,
and then press the DRYER POWER
STOP button to reset the circuit.
Press the START button.