SERIES 2000 ERROR CONDITIONS

SERIES 2000 ERROR CONDITIONS

SERIES 2000 ERROR CONDITIONS

SERIES 2000 ERROR CONDITIONS

SERIES 2000 ERROR CONDITIONS

ERROR CODE BREAKDOWN

ERROR CODE BREAKDOWN

ERROR CODE BREAKDOWN

ERROR CODE BREAKDOWN

ERROR CODE BREAKDOWN

COMPETITOR ERROR CONDITIONS

This indicates that one of the other on

screen errors (vapor, plenum, housing

temp hi-limit, flame out, no airflow, motor

overload or rear discharge) has occured.

Mercoid gas pressure safety.

User supplied safety.

I/O board communication failure

I/O board and master have lost

communication.

No safety circuit voltage.

Illegal flame sense. Error 7 is most likely

caused by stuck open solenoid. Error 7 will

not shut down fan until loss of flame is

detected by control. Error 7 may also be

caused by a bad ballast resistor (ballast

resistor not open between poles). It may also

occur if 1 of the 12 volt DC limits is shorted to

AC ground, or either temperature senosr is

shorted to AC ground.

Flame probe shorted to AC ground.

Plenum temperature senosr leads are

shorted together OR sensor is shorted.

(See figure 4)

Plenum temperature sensor is open.

One or both leads are off (open circuit)

(See figure 4)

Grain temperature sensor leads are

shorted together OR sensor is shorted.

(See Figure 4)

Grain temperature sensor open. One

or both leads are off (open circuit)

(SEE FIGURE 4)

User switched from continuous flow to

batch while dryer is running.

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR

ERROR