Installation, Chapter 2 installation, Top auger motor – Grain Systems PNEG-1764 User Manual
Page 7
Advertising
PNEG-1764 Leeson Motor Field Installation for 5 HP Load and 7-1/2 HP Unload Applications
7
2. Installation
Top Auger Motor
1. Remove the belts and sheave from the motor shaft.
2. Replace the present 712-1 Baldor motor with the D03-1010 Leeson motor.
3. Install new 28138-2 sheave on motor shaft.
4. Re-install belts and adjust tension.
5. Re-install belt guard.
Figure 2A Top Auger Drive Components
New sheave
(28138-2)
New motor
(D03-1010)
Revisions for leeson motor
Advertising