Smart board – Grain Systems PNEG-377 User Manual

Page 67

Advertising
background image

67

Fan and Heater

SMART BOARD

Fan and Heater

"SMART BOARD" is the name of the new printed

circuit board in your heater. The purpose of this new

board is to simplify the procedure for checking out

the heater in case of a malfunction. "SMART

BOARD" uses a series of lights to check for power at

various locations in the heater circuit. Lights that are

lit have power going to those components or loca-

tions, lights that are not lit indicate a lack of power at

the terminal or location. During the operation of the

heater, some check points should have power and

some should not have power. The lights are num-

bered (1 through 7, A and B). Following is informa-

tion to help identify which lights should be lit, what

problem may exist and explain the operation of the

SMART BOARD.

Standard Heaters ( not HI-LO fire):

When standard heater units are first turned on the and

the purge time is completed (10 seconds), auto-check

lights #1 through #6, A and B should be lit. When

flame is established A and B will drop out. Light #7

is used only on HI-LO fire units and does not function

on standard units.

HI-LO Fire Heater

On HI-LO fire units, all of the light sequences are the

same as on standard units, except light #7 will be lit

on high flame, and goes out when switching to low

flame.

When the plenum chamber reaches the preset tem-

perature of the humidistat-thermostat, lights 1 and 2

will be lit all other lights will be out. Once the flame

goes out, light A will be lit and after the purge delay,

lights 3 and 4 will be lit also. When the plenum

chamber cools to the point of requiring more heat,

lights 5 and 6 will be lit again. The cycle should

continue until the unit is shut off.

The information below lists the light number(s) and

what they indicate. Follow the chart down to the

appropriate condition the unit is in, then read across

to the explanation. Once the problem has been

identified, you can proceed to fix the problem.

NOTE: Remove power and inspect all electrical

connections before any other troubleshooting. If any

connections are loose, tighten them and retry opera-

tion.

If a problem should occur, by

following the instructions, the

reason a heater does not maintain

flame should be easily deter-

mined. As with any trouble-shooting, do not put

ANYTHING inside the electrical box when the unit

has power supplied to it. Be sure power is discon-

nected at the breaker before servicing.

If the heater unit does not operate properly, remove

the electrical box cover and look at the Auto-Check

board. By looking at the lights on the board, the

problem should be easily identified. With the on-

off switch on, determine which lights are lit and

which are not.

Advertising