Column joints with diagonal “x” bracing (cont.) – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1412 User Manual

Page 20

Advertising
background image

20

PNEG-1412 Two Leg Towers

5. For “X” Bracing where a lateral bracket
is used instead of a web plate, see
Figure 8.

6. Install an “H” Channel Brace
(STC00350) to the top of the columns
and “X” bracing as shown using (4) 1/2" x
1" HHCS bolts and nuts. (See Figure 9.)

Column Joints with Diagonal “X” Bracing (cont.)

Figure 8

Figure 9

1/2" x 1"
HHCS
Bolt
(S-4492)

1/2" Hex Nut
(S-3729)

1/2" Flat
Washer
(S-2120)

Column

Lateral Bracket
(STC00355)

3/8" Flat
Washer
(S-248)

3/8" Hex
Nut (S-456)

3/8" x 1"
HHCS Bolt
(S-8671)

Diagonal “X”
Brace (STC00351)

3/8" Spacer
(STF00022)

Bin Bracket
(STF00016)

Backing Plate
(STF00021)

“H” Channel Brace
(STC00350)

Column

1/2" x 1"
HHCS Bolt
(S-4492)

1/2" Hex Nut
(S-3729)

Diagonal “X” Brace
(STC00351)

1/2" Hex Nut
(S-3729)

1/2" x 1"
HHCS Bolt
(S-4492)

Advertising