6. Operation
PNEG-1049 10"-12" Commercial Bin Sweep Augers
31
10. When the grain flow stops from the center well, close the center well gate. The remaining grain should
look like
Figure 6C
11. Gradually open the center well and inside intermediate wells until the desired flow has been established.
DO NOT excessively open the gates, as the flow of grain into the inside intermediate wells and
occasional grain flow into the center well will be at a higher rate than what the unload system can
remove. This will cause the auger to plug or “jam”.
12. Always close the well gates and allow the unload auger to clean out before stopping the unload auger.
13. When the grain flow stops from the center well and inside intermediate wells, close the center well and
intermediate well gates. The remaining grain should look like
Figure 6D