PNEG-1499 High / Low Thermostat

ELECTRICAL CONNECTION

Standard electrical safety practices and codes

should be used when working with a heater. Refer

to the National Electric Code Standard Handbook

by the National Fire Protection Association. A quali-

fied electrician should make all wiring installations.

DANGER

ALWAYS DISCONNECT AND LOCK OUT POWER

BEFORE WORKING ON OR AROUND HEATER.

Thermostat Connection to Standard Terminal

Strip on heaters built prior to 2007.

1.

Connect power cord to fan control box.

2.

Connect the BLACK 120VAC power wire

to terminal 2.

3.

Connect the WHITE Neutral wire to

terminal 8.

4.

Connect the GREEN Stage 1 Common wire

to terminal 6.

5.

Connect the RED Stage 1 N/O wire

to the high/low light and cycle solenoid.

6.

Connect the ORANGE Stage 2 Common

wire to terminal 8.

7.

Connect the BLUE Stage 2 N/O wire to terminal 5.

Advertising