PNEG-1499 High / Low Thermostat

INSTALLATION

1.

Mount the thermostat control on the right side of

the fan transition. Locate a suitable location on the

bin wall that will allow the power cord to reach the

heater and the control to be at eye level for easy ac-

cess.

2.

Use the S-280 self-drilling screws provided in the

packaging to mount the control.

3.

Run the power cord to the heater control box and

make the connections as shown in the electrical con-

nection section of this manual.

4.

Mount the thermostat sensor 24” to the RIGHT of

the transition. Use the C-8058 Sensor Mounting Plate

as a template. This part has holes to match the hills of

a 2.66” and 4.00” bin sidewall.

5.

Use the S-280 screws provided to mount the C-8058

plate on the sidewall. The large hole on the plate should

be centered on a valley of the bin corrugations. The

plate should be mounted approximately in the center of

the plenum at the closest valley.

6.

Use the hole in the mounting plate as a guide and

drill a pilot hole. Once the pilot hole is drilled in the

sidewall, remove the mounting plate.

7.

With the plate removed, enlarge the pilot hole to 1/

2” diameter.

8.

Attach the Sensor of the thermostat to the mounting

plate using the C-8057 Cord Connector. The Sensor

should extend approximately 3.00” beyond the plate. If

not, then adjust the sensor length by loosening the cord

connector and moving the Sensor.

9.

Insert the Sensor into the 1/2” hole and reattach the

mounting plate using the S-280 screws.

10. Caulk the area around the mounting plate to seal

any openings.

Mount the Sensor approximately 24” to the

RIGHT of the transition.