Electrical connection – Grain Systems PNEG-1499 User Manual

Page 11

Advertising
background image

11

PNEG-1499 High / Low Thermostat

ELECTRICAL CONNECTION

Thermostat Connection to Standard Terminal

Strip on heaters built in 2007 to present.

1.

Connect power cord to fan control box.

2.

Connect the BLACK 120VAC power wire

to the ON / OFF switch. Make this connection so

this switch will also control the thermostat power.

3.

Connect the WHITE Neutral wire to terminal 8.

4.

Connect the GREEN Stage 1 Common wire

to terminal 6.

5.

Connect the RED Stage 1 N/O wire

to the high/low light and cycle solenoid.

6.

Connect the ORANGE Stage 2 Common

wire to terminal 1.

7.

Connect the BLUE Stage 2 N/O wire to high limit

circuit on the incoming L1 power.

Note: Terminal strip may or may not be present in heater

to connect wires in thermostat circuits.

Advertising