Series 2000 software changes – Grain Systems PNEG-692 User Manual

Page 12

Advertising
background image

1998 Service School Top Dry

12

SERIES 2000 SOFTWARE CHANGES

Software Version 0.20

Created a option in the set-up

mode: L or no L

If L is selected, the Dry timer

has to be at zero and the grain

temperature has to be at the

desired setpoint before the unit

will advance to the cool cycle.

Significant Software changes since July 12, 1995

(Software version number is displayed at all units on power-up)

Software Version 0.10

The fan, on any fan/heater unit, will not

shut off if flame is sensed illegally until

flame is no longer sensed.

Software Version 0.12

When a shutdown occurs while drying

you can view the number of hours since

the shutdown by pressing the decrease

switch.

Limited the maximum temperature

setting to 230 degrees F.

Software Version 0.14

You can change the Dry and Cool

times while the dryer is running, press

the increase and decrease switches at

the same time after the new times have

been entered and the program mode

exited, and the new times will be

loaded immediately.

Holding the increase switch while

pressing the start switch will start both

the fan and heater in a continuous heat

cycle. 99.9 hours will be displayed on

the screen forever or until the unit is

powered down.

Holding the decrease switch while

pressing the start switch will start both

the fan and heater in a continuous cool

cycle. 99.9 hours will be displayed on

the screen forever or until the unit is

powered down.

Software Version 0.15

On some errors you could not view the

hours since shutdown-fixed that prob-

lem.

Software Version 0.17

On two fan units, when the slave shut

down the master fan would not shut

off-fixed that problem.

When a limit error is given the screen

now says: 000 instead of just dis-

playing the temperature.

Software Version 0.18

The dryer will not advance to the cool

cycle for at least ten minutes after start-

up. This allows the grain temperature

sensor to stabilize.

Fixed a problem with display flicker on

two fan units.

Software Version 0.19

Added software for a humidity sensi-

tive controller.