1998 Service School Top Dry

13

SERIES 2000 SOFTWARE CHANGES

If L is selected, the dryer timer

has to be at zero and the grain

temperature has to be at the

desired set point before the unit

will advance to the cool cycle.

If no L is selected, the dry

timer has to be at zero or grain

temperature has to be at the

desired set point before the unit

will advance to the cool cycle.

If the grain temperature exceeds 200

degrees F, after the initial 10 minutes

of the dry cycle, the dryer will advance

to the cool cycle.

In some instances the plenum tempera-

ture would jump to 275 degrees F -

fixed that problem.

Software Version 0.21

When in the Top Dry mode the heater

is always set up as a hi-lo fire unit.

Software Version 0.22

When setting the dry time to 3.2 hours

the display would say .32 hours when

the program mode was exited - fixed

that problem.

Clearing the NOVRAM is now down

by powering up with the program

temperature switch held down, press

the increase switch until a 7 is dis

played and press the program tempera-

ture switch again. You have two

seconds to press the increase and

decrease switches at the same time to

clear the NOVRAM.

Software Version 0.23

By placing dipswitch #3 in the

“on” position you can disable

the airswitch test.

In the Top Dry mode, if J5-3 and J5-4

are shorted together the unit will jump

immediately to the cool cycle, even if

the dryer has been running less than 10

minutes.

Significant Software changes since July 12, 1995,continued

(Software version number is displayed at all units on power-up)