1997 Grain Temperature Sensor Update Kit Installation Instructions

Packing List:

1) TF-1425

TD Series 2000 Grain

Temperature Sensor

Assembly

2) S-275

Bolt 5/16-18 x 3/4

3) S-396

Nut 5/16 - 18 Hex

(1) PNEG-629

TD ‘97 Grain

Temperature Update Kit

Instructions

Tool Required:

One pair of wire cutters

One pair of wire strippers

Two 1/2” wrenches

One regular screwdriver or Entrelec terminal

tool (depends on what type of terminals the unit

has)

Installing the new grain

temperature sensor assembly:

1)

In the control box remove the two wires

from the terminal block for the old grain

temperature sensor (opposite J7-18 and

J7-14 on the terminal strip).

2)

Remove the cord from the control box.

3)

Remove the old temperature sensor and

sensor housing from the leveling band

post (the temperature sensor is still good

and can be kept).

4)

Mount the new grain temperature sensor

bracket to the outside leveling band post

using the 3 supplied nuts and bolts so

that the temperature sensor is 19 1/12”

above the floor sheet rib.

5)

Run the cord from the grain tempera-

ture sensor up the leveling band post

and across the top leveling band to the

point closest to the fan/heater unit.

6)

Take the cord out of the drying cham-

ber through the bin eave.

7)

Run the new grain temperature sensor

cord through the Heyco cord connector

in the control box that was used by the

old grain temperature sensor.

8)

Install the two wires in the cord from

the new temperature sensor in the

terminal block where the wires from the

old temperature sensor were removed

(opposite J7-18 and J7-14 on the

terminal strip).