1997 AIRSWITCH UPDATE

1997 Airswitch Update Kit Installation Instructions

Packing List:

(1) TF-1278

TD Airswitch assembly

(1) FH-1310

Heyco cord connector

(1) FH-1309

Lock Nut 1/2”

(4) S-280

Screw #10- 16 x 5/8 self

drill

(1) PNEG-628

TD ‘97 Airswitch Update

Kit Instructions

Tool Required:

One pair of wire cutters

One pair of wire strippers

One drill with a 5/16” nut driver and 3/4” drill

bit

One regular screwdriver or Entrelec terminal

tool (depends on what type of terminals the unit

has)

Installing the new airswitch:

1)

On either side of the master fan/heater,

drill one 3/4” hole even with the fan/

heater unit in a valley on the bin

sidewall.

2)

Insert the airswitch probe through the 3/

4” hole.

3)

Position the housing so the cord exists

the housing horizontally, and the vents

open downward.

4)

Use the four self drilling screws to

mount the housing to the bin sidewall.

5)

Caulk between the housing and the

sidewall to seal.

6)

Remove a knockout in the fan control

box on the master heater.

7)

Install the Heyco cord connector in the

knockout hole.

8)

Run the cord from the airswitch through

the Heyco cord connector and into the

control box.

9)

Tighten the Heyco cord connector onto

the cord.

Wiring the new airswitch:

1)

Remove the three wires from the termi-

nal strip that are attached to the old

airswitch (opposite J7-9, J7-11 and J7-

10 on the terminal strip).

2)

Attach the green wire from the cord on

the new airswitch to the terminal strip

opposite J7-09.

3)

Attach the white wire from the cord on

the new airswitch to the terminal strip

opposite J7-11.

4)

Attach the black wire from the cord on

the new airswitch to the terminal strip

opposite J7-10.

5)

In two fan units, place dipswitch #3 on

the slave fan/heater in the “on” position.

This will bypass the old airswitch in the

slave unit.

6)

When starting the dryer with grain in the

drying chamber make sure that the

airswitch does not close until both units

are half speed.

Advertising