13

4. Setup Screens

Special Network Dryer Setup Screens

There are certain dryer features that rarely need to be changed and which should be carefully considered
before adjusting. To access these advanced features, with the power OFF, press and hold the MODIFY
button and then turn ON the control power for the dryer. Release the MODIFY button and the advanced
feature screens will be available.

Pressing ENTER after releasing the Modify button will allow you to view and/or change the special setup
screens in the following sequential order:

Selections in bold are the default settings

Series 2000 Fan and Heater Dip Switch Settings:

NOTE: These are set at the factory but will need to be reset when changing out a board.

Fan 1 #1 OFF / All Others ON
Fan 2 #2 OFF / All Others ON
Fan 3 #1 and #2 OFF / All Others ON
Fan 4 #3 OFF / All Others ON
Fan 5 #1 and #3 OFF / All Others ON
Fan 6 #2 and #3 OFF / All Others ON

Option

Select

1. Turn Meter Rolls OFF

No——Yes

2. Air Switch Testing

Yes——No

3. Meter Roll Reverse

No——Yes

A. Reverse Time

5 Minutes, but is adjustable

B. Forward Time

55 Minutes, but is adjustable

4. Select Unload Method

2 Speed——3 Speed

5. Select Dryer Address

01——for use with the Watchdog program only

6. Attempt to Refill

No——Yes

7. Enter Model Number

Dryer Model Number NOTE: Dryer Model Number must
be exact in order for the dryer to operate properly.

8. Temperature Scale

Fahrenheit——Celsius

9. Change Burner Setup

Enter to Change——Reset to Bypass

A. High/Low Fire or ON/OFF Fire

High/Low Fire——ON/OFF Fire

B. Active or Inactive

Active——Inactive

10. Set Time and Date

Time and Date

11. Load System

End Fill——Center Fill——Dual Fill

12. Unit of Measure

Bushels——Metric Tons

13. Change Burner Differential

Enter to Change——Reset to Bypass

A. Set Burner Differential in Degrees

Default is 3 Degrees in High/Low and 1° in ON/OFF Fire
This default is not effective until software version 1.16