Installation and Setup

Installing a Rear I/O Module

RM20-9083-F

Provides the following connections:

• HD/SD-SDI coaxial input (SDI IN)

• Five AES coaxial inputs (AES IN 1 thru AES IN 4;

AES IN 8)

• Two dedicated AES coaxial audio outputs

(AES OUT 1 and AES OUT 2)

• Two buffered SDI coaxial outputs (SDI OUT 1 and

SDI OUT 2)

Note: For AES IN 1 thru AES IN 4 on RM20-9083-F

Rear I/O Module to function as inputs, AES I/O
switches S11 – S14 must be set to Input
(factory default). See Setting I/O Switches for
AES I/O (1-4) Ports (p. 2-1)
for more
information.

RM20-9083-G

Provides the following connections:

• HD/SD-SDI coaxial input (SDI IN)

• Two HD/SD-SDI reclocked input copies

(RCK OUT 1 and RCK OUT 2)

• Four dedicated AES coaxial audio inputs

(AES IN 5 thru AES IN 8)

• Four AES I/O coaxial input/outputs (AES I/O 1 thru

AES I/O 4; I/O function of each connection is
user-configurable)

• Eight dedicated AES coaxial audio outputs

(AES OUT 1 thru AES OUT 8)

• Eight analog balanced audio inputs (AN-AUD IN 1

thru AN-AUD IN 8)

• Two buffered SDI coaxial outputs (SDI OUT 1 and

SDI OUT 2)

Note: For AES I/O 1 thru AES I/O 4 on

RM20-9083-G Rear I/O Module to function as
inputs, AES I/O switches S11 – S14 must be
set to Input (factory default).
See Setting I/O Switches for AES I/O (1-4)
Ports (p. 2-1)
for more information.

Note: AES OUT 1 thru AES OUT 4 on

RM20-9083-G Rear I/O Module always
function as outputs regardless of whether
AES I/O 1 thru AES I/O 4 are used as inputs
or outputs.

Table 2-1

9083 Rear I/O Modules — continued

9083 Rear I/O Module

Description