2. Display function description

From left to right, that first digital indication:

A. Stand for auto real-time measuring;

b. Stand for the set temperature;

The second, third and forth digital indicate the temperature

degree, the six and seventh digital indicate the airflow in

percentage;

3. Operating Instructions

When connected power plug, the device starts to work,

temperature display indicate ”A100” and air flow display indicate

“F15”. After adjust temperature and air then begin to use.

3-1 Adjust Temperature (Up)

Press “C1” button to adjust temperature, after release the

button, “A100” will be indicate on the temperature display after 2

seconds star to heating and temperature rise.

When temperature up to specified temperature, the

heating element will stop to heating and keep the

temperature, the Indicator light shifting from successive

shining to intermittent shining.

3-2 Adjust Temperature (Down)

Press “C2” button, temperature begin to drop until reach

specified temperature. For example, in order lower

temperature from constant state of 380 degree to 180 degree

(as illustrated as follow) constant temperature“A380”

Press the second button from the left.→ “b380”

→“b180”→release the button →“A380”。