3-3 Set Airflow

Press “C3” button, airflow indication change from “F15” to

“F18”, and airflow starts to increase; release the button

when it reaches “F99”, the glass ball that in the airflow

meter will rising to the top, indicating the max airflow.

Press “C4” button, airflow indication change from“F99”to

“F96”, airflow starts to decrease; release the button when it

reaches “F06”, the minimum for no airflow.


4 How to Use the Reset Button (

Press “D” button, device returns to stand-by State,

temperature indicated “A100”and airflow indicate “F15”.

Caution: Do not press reset button when device at

Maximum temperature. Adjust temperature and waiting for

temperature drop to the minimum then pressing the reset

button, for avoid damage on the heating unit and the handle.


5

How to Use the Handle Switch (s

Touch on/off switch that on the handle; when you put the

handle back to the holder, the switch will be triggered on.

When the switch is triggered on, the heating unit will stop to

heating immediately; after the handle remains unused for 5

minutes, temperature display will indicator “E” and device

automatically shut-off state to save power; when you pick up the

handle again the appliance will recover the previous set state.

5-1 Sleep Mode Timer Set-Up

Switch the unit ON (or press “Reset” button “D” from the

panel). Press and hold C3 while the banner is scrolling.

Display panel, B2, will initially indicate ‘L05’, which means the

device will switch to sleep mode after 5 minutes (default) of

idle time and if the nozzle is docked on the handle for the

duration of time. Adjust the time before sleep by pressing buttons

C1 or C2. Press C4 to confirm. The device will start counting

down when the hot air gun is docked on the handle. Once

countdown is finished and the hot air gun still docked, the

Advertising