Prokit's Industries SS-952B User Manual
Page 6
![background image](/manuals/286907/6/background.png)
5
device will automatically blow air (at room temperature) to bring
down temperature to 90 The panel will then display the
℃
following after reaching the safe temperature level and to indicate
that the device is now in sleep mode.
NOTES:
Time is configurable from 1 to 20 minutes (default 5
minutes).
The device has a switch located at the handle (cradle),
which activates the countdown before the system goes to
sleep.
Once the hot air gun is released from the handle during
sleep mode, the unit will automatically switch back to
previous working temperature and airflow level parameters.
6. Replacement the Heating Element
6.1 Replacement
Parts
Item
Specification
5SS-952BC-F-H
Heating element
(210V-240V ) 250W
6-2 Replacement the Heating Element
Loosen the screw, slide the tube loosen the 3 screws,
which secure the handle. Then slide the cord and the cord
tube.
Open the handle disconnects the ground wire sleeve, and
remove the pipe, in the pipe, the quartz glass and heat
insulation is installed. Do not drop or miss it. Take out the
heating element loosen the cable. And take out the heating
element.
Insert new heating element handles it with care. Never rub
the Heating Element wire Insert a new heating element and
reconnect the terminal. Reconnect the ground wire after
replacing the element .Assemble the handle in the reverse
order of disassembly. Insert the handle’s projection into the
hole in the pipe.