Prokit's Industries SS-952B User Manual

Page 6

Advertising
background image

5

device will automatically blow air (at room temperature) to bring

down temperature to 90 The panel will then display the

following after reaching the safe temperature level and to indicate

that the device is now in sleep mode.
NOTES:

Time is configurable from 1 to 20 minutes (default 5

minutes).

The device has a switch located at the handle (cradle),

which activates the countdown before the system goes to

sleep.

Once the hot air gun is released from the handle during

sleep mode, the unit will automatically switch back to

previous working temperature and airflow level parameters.

6. Replacement the Heating Element

6.1 Replacement

Parts

Item

Specification

5SS-952BC-F-H

Heating element
(210V-240V ) 250W

6-2 Replacement the Heating Element

Loosen the screw, slide the tube loosen the 3 screws,

which secure the handle. Then slide the cord and the cord

tube.

Open the handle disconnects the ground wire sleeve, and

remove the pipe, in the pipe, the quartz glass and heat

insulation is installed. Do not drop or miss it. Take out the

heating element loosen the cable. And take out the heating

element.

Insert new heating element handles it with care. Never rub

the Heating Element wire Insert a new heating element and

reconnect the terminal. Reconnect the ground wire after

replacing the element .Assemble the handle in the reverse

order of disassembly. Insert the handle’s projection into the
hole in the pipe.

Advertising