Diagram #5, Diagram #6 diagram #7, Diagram #4 – Derale Performance High Output Dual Rad Fan Assembly User Manual

Page 2

Advertising
background image

Derale Performance, Los Angeles, CA

800.421.6288

www.derale.com

THERMOSTAT INSTALLATION

Option 1

FAN #1 - 180° Thermostat Switch

Option 1 - Push-in Radiator Probe

Option 2 - Thread-in Radiator Probe

Identify the small bag labeled “180°F Thermostat Kit”

Fan #1 has two thermostat probe options. Choose the option below
that best fits your application.

(See Diagram #4)

(See Diagram #6)

For best results we recommend installing the probe as close as

possible to the water inlet of the radiator. (See Diagram #5)

1.

Take the brass probe and thread it clockwise onto the thermostat.

2.

Carefully insert the probe/thermostat assembly into the fins of the radiator until thermostat is flush with radiator.

3.

Install the 1 x 1 foam pad onto the Push-in Probe.

4.

Install Retaining Clip onto the Push-in Probe until tight. (See Diagram #4)

Placement:

Installation:

Push-in

Radiator

Probe

Down-flow Radiator

Diagram #5

Push-in

Radiator Probe

Water

Inlet

Water

Outlet

Cross-flow Radiator

Water

Inlet

Option 2

Placement:

Installation:

Note:

Locate a 3/8” NPT port either on the radiator, waterneck, intake
manifold or cylinder heads.

1.

Using Teflon tape or suitable sealant install the probe into the 3/8” NPT port

on the vehicle.

2.

Using a 3/4” wrench tighten the probe.

3.

Carefully thread the Thermostat Switch clockwise into the Thread-in Probe now

installed on the vehicle. Sealant such as Loctite can be used for permanent
installation. (See Diagram #6)

DO NOT TIGHTEN THERMOSTAT WITH A WRENCH, HAND TIGHTEN ONLY.

Thermostat
Switch

3/8” NPT

Thread-in Probe

Diagram #6

Diagram #7

FAN #2 - 190° Thermostat Switch

Identify the small bag labeled “190° Thermostat Kit”

Fan #2 requires a threaded port either 1/8” NPT or 3/8” NPT.
(See Diagram #7)

Locate a port on the vehicle,

found on the

vehicles radiator, manifold or water outlet.

Using Teflon Tape or suitable sealant

install the Thermostat Switch into the port on the vehicle.

Using Teflon Tape or suitable sealant

install the 3/8” x 1/8” NPT Reducer Bushing into the 3/8” NPT port on
the vehicle. Using Teflon Tape or suitable sealant install the Thermostat
Switch into the 3/8” x 1/8” NPT Reducer Bushing.
(See Diagram #7)

Placement:

generally

1/8” NPT port installation -

3/8” NPT port installation -

3/8”

NPT

3/8”

NPT

1/8”

NPT

1/8”

NPT

1/8”

NPT

1/8”

NPT

Thermostat
Switch

Radiator

Foam Pad

Retaining

Clip

Push-in
Probe

Diagram #4

(Page 2)

Advertising