Diagram #9, Diagram #8, Relay #1 relay #2 – Derale Performance High Output Dual Rad Fan Assembly User Manual

Page 3

Advertising
background image

Derale Performance, Los Angeles, CA

800.421.6288

www.derale.com

Blue

Fan Positive (+)

30Amp Fuse

Ignition
Switch

Black

Chassis Ground (-)

Red

30

86

85

87

Green

12 Volt Positive (+)

Battery

180°F

Thermostat Switch

Orange

Diagram #9

Yellow

RELAY WIRE HARNESS MOUNTING

1.

Find a convenient location, taking into consideration Thermostat
placement and wire routing requirements. Avoid mounting near
HOT engine components.

2.

Using the Relays as a template, mark and drill two 5/32” holes.

3.

Using the two #10 Sheet Metal Screws provided and a standard
screw driver or 5/16” nut driver, attach the two Relay Harnesses.
(See Diagram #8)

RELAY #1

RELAY #2

FAN MOTOR

Red

86

30

87

85

Ignition
Switch

Green

Override Circuit

(Optional)

190°F

Thermostat Switch

Yellow

30Amp Fuse

Orange

RELAY

#1

Mounting

Surface

RELAY

#2

Diagram #8

FAN MOTOR

Orange

Orange

Blue

Fan Positive (+)

Black

Chassis Ground (-)

Override Circuit

(Optional)

12 Volt Positive (+)

Battery

#1

#2

ELECTRIC FAN WIRING

RELAY HARNESS WIRING

Black Wires -

BOTH

FAN #1

Blue Wire -

ORANGE Wire

FAN #2

Blue Wire -

ORANGE Wire

Black Wires -

BOTH

RELAY #1

Red Wire -

Yellow Wire -

EITHER

Thermostat Switch Wire -

Note:

Orange Wire -

Green Wire - Override Circuit (Optional)

Using the Blue #10 Ring Terminal and #10 Sheet Metal Screw provided, attach

Black wires coming from

the Electric Fans to a good chassis Ground (-).

Using the Blue Butt Connector provided, attach the Blue Positive (+) fan wire to the

on Relay #1.

Using the Blue Butt Connector provided, attach the Blue Positive (+) fan wire to the

on Relay #2.

Using the Blue #10 Ring Terminal and #10 Sheet Metal Screw provided, attach

Black wires coming from

the Electric Fans to a good chassis Ground (-).

Using the Blue 5/16” Ring Terminal provided, attach the Red wire directly to the vehicles Positive (+) battery

terminal.

Using the Blue Butt Connector provided, attach the Yellow Wire to

wire on the 180° Thermostat Switch.

Using the Red Butt Connector, Blue Wire Tap Connector and Wire provided, attach the remaining

Thermostat Switch Wire to a Positive (+) switched ignition source.

If the Yellow Wire is connected to a constant power source (battery) the electric fan will run after the vehicle has been

shut off and could run down the battery.

See Electric Fan Wiring

The Green Wire is designed to work in two different configurations. When used, this will allow the fan to be turned on
regardless of the temperature of the thermostat as it simply overrides all other functions. If you choose to not use this option,
cut any exposed copper and tape or shrink wrap the end of the wire.

(Page 3)

WIRING

Before starting, disconnect the Negative (-) cable on the vehicles battery.

Using the electrical connectors and wire ties provided, follow the directions below. (See Diagram #9)

When extending wires always use the identical gauge wire as provided.

Identify which Relay will be used for Fan #1 and Fan #2 and temporarily mark using a piece of tape and pencil.

WARNING: