Appendix – OSRAM DUO User Manual
Page 4

Page 4 of 4
Appendix
Technical data
Operating voltage
220-240 V/50-60 Hz
(no DC operation)
Fuse
External 6 A (10 A)
Power consumption
Switched on: Approx. 1 W
Switched off: Approx. 0.7 W
Maximum total line
length
100 m
Switch output
Floating contact (internal relay, make
contact)
Switch output load
capacity
Resistive load: 10 A/250 V AC,
6 A/30 V DC
Ohmic lamp load: 5 A
Inductive load: 5 A
30 x single-lamp ECG 18 W
20 x two-lamp ECG 18 W
30 x single-lamp ECG 36 W
20 x two-lamp ECG 36 W
20 x single-lamp ECG 58 W
10 x two-lamp ECG 58 W
Detection area
Max. Ø 12 m
Installation height
Max. 5 m (ideal: 2.5 - 3 m)
Switching hysteresis
Approx. 15%
Operating temperature
0 °C ... +50 °C
Protection class
II
Protection type
IP 20
Weight
Approx. 150 g
Dimensions (L x W x H)
58.5 x 70.5 x 47 mm
Dimensioned drawing
Conformity with the relevant EU directives is