Dimensioned drawing
Appendix
Technical data
Transmission
power
10 mW
Operating
temperature
0 °C ... +50 °C
Frequency band
868.3 MHz
Switching cycles > 50,000
Functional range In the open air: Approx. 300 m
Halls: Approx 100 m
Passageways and corridors: Approx. 50 m
Rooms with wooden or plasterboard walls:
Approx. 30 m (max. 7 walls)
Rooms with brick or autoclaved aerated
concrete walls:
Approx. 20 m (max. 3 walls)
Rooms with reinforced concrete walls:
Approx. 10 m (max. 1 wall)
Protection type
IP 20
Dimensions
(L x W x H)
80 x 80 x 17.5 mm
70,0 mm
70,0 mm
60,0 mm
60,0 mm
17,5 mm
80,0 mm
80,0 mm
Conformity with the relevant EU directives is