OSRAM PrevaLED Core Z3 User Manual
Page 10

10
PrevaLED
®
Core Z3 LED modules
|
Electrical considerations
3.3 Wiring
The input clamps used in the PrevaLED
®
Core Z3 can hand-
le solid wires with a cross-section of 0.5–1.0 mm
2
(AWG 21-17).
Example: H05V-U 1x 0.5 mm2
Please note:
— The connector is designed for three “poke-in” and
release cycles.
— The installation of LED modules needs to be carried out
in compliance with all applicable electrical and safety
standards. Only qualifi ed personnel should be allowed to
perform installations.
— If you cannot use solid wires, you can use stranded wires
with a diameter of 0.5 to 0.75 mm and tin-coat the wire
ends before inserting them into the connection clamp.
For wires with
1 mm
2
(AWG17):
5.5 mm
For wires with
0.5-0.823 mm
2
(AWG21–18):
5.3 +- 0.2 mm
Wire preparation