Appendix – OSRAM Touch DIM RC User Manual

Page 2

Advertising
background image

Page 2 of 2

OSRAM GmbH

Kunden Service Center

Customer-Service-Center (CSC)
Steinerne Furt 62

86167 Augsburg

Germany
Tel : +49 (0) 1803 677 - 200

(kostenpflichtig / charges apply)

Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de

40083210319382

4008321031938

IV 2009
TOUCH-DIM-RC_ma0904en_we1.01.indd

Dimensioned drawing

Appendix

Technical data

Operating voltage

220-240 V / 50-60 Hz

Current consump-

tion

Approx. 9 mA

Power consump-

tion

Max. 1.5 W

Inputs (learn,

T1, T2)

Inputs for floating make contacts

Outputs (Ch 1,

Ch 2)

Floating semiconductor relay, max.

45 mA / 240 V

Load capacity of

signal output

(electronic control

gears per output)

Max. 15 QTi DALI ECG or HTi trans-

formers

or 15 QT DALI ECG

Max. number of

wall-mounted/

hand-held trans-

mitters

30

Operating tempe-

rature

0 °C … +50 °C

Frequency band

868.3 MHz

Integrated over-

heating protection

Resets independently, not replaceable

Functional range

In the open air: Approx. 300 m
Halls: Approx 100 m
Passageways and corridors: Approx.

50 m
Rooms with wooden or plasterboard

walls: Approx. 30 m (max. 7 walls)
Rooms with brick or autoclaved aerated

concrete walls: Approx. 20 m (max. 3

walls)
Rooms with reinforced concrete walls:

Approx. 10 m (max. 1 wall)

Protection class

II

Protection type

IP 20

Dimensions

(L x W x H)

189 x 30 x 21 mm

Conformity with the relevant EU directives is

confirmed by the CE symbol.