DN-31 Store Data Values

Option:

Function:

Parameter values changed via DeviceNet are

not automatically stored in non-volatile

memory. Use this parameter to activate a

function that stores parameter values in the

EEPROM non-volatile memory, so changed

parameter values will be retained at power-

down.

[0]

*

Off

Deactivates the non-volatile storage function.

[1]

Store edit

setup

Stores all parameter values from the active set-

up in the non-volatile memory. The selection

returns to [0] Off when all values have been

stored.

[2]

Store all

setups

Stores all parameter values for all set-ups in the

non-volatile memory. The selection returns to

[0] Off when all parameter values have been

stored.

DN-32 Devicenet Revision

Range:

Function:

0

*

[0 - 65535] View the DeviceNet revision number. This

parameter is used for EDS file creation.

DN-33 Store Always

Option:

Function:

[0]

*

Off

Deactivates non-volatile storage of data.

[1]

On

Stores parameter data received via DeviceNet in

EEPROM non-volatile memory as default.