Figure 32 controller wiring – GE Industrial Solutions CPS3200U User Manual

Page 34

Advertising
background image

CPS3200U Upstream System – 23” Product Manual

CPS3200U

CC848779826 r09 December 2013

34

Step

Action

6.

Attach signal wiring to the controller at connector P6. The Ethernet connection to the local

network is made through the P6 RJ45 connector. Of the two RJ45s on the left side of the

controller, P6 is the one more toward the front labeled: P6 10/100 Base-T. Plug the local

network cable into P6. As shown here:

Figure 32 Controller Wiring

7.

To check the network connection, use the controller display to determine what IP address has
been assigned to the QS941 controller. Press the square key,

■,

on the upper right hand corner

of the keypad to display the menu.

8.

Press the down arrow key,

▼, 2 times to scroll down to the “Status” item on the menu.

9.

Press the right arrow,

, to advance to the “Status” menu.

10.

Press the down arrow key,

▼, 8 times to scroll down to the “Network Settings” item and select

by pressing the right arrow key.

11.

Press the right arrow,

▼, to advance to the “Network Settings” menu.

12.

Press the right arrow,

, to select Port 1. The P6 connector is Port 1.

13.

Read and record the network address for Port 1.

When an IP address is listed connection to the server is confirmed.