Program Return Value –

0x00

SUCCESS: command completed successfully.

0x01

FAILURE: command failed.

Sample Output –

Here is an example of the status information returned when a volume
resynchronization is in progress:

Background command progress status for controller 0...
IR Volume 1
Current operation : Synchronize
Volume ID : 6
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
Volume size (in sectors) : 70311936
Number of remaining sectors : 68250624
Percentage complete : 2.93%

Here is an example of the status information returned when no
background volume operation is in progress:

Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 6
Volume status : Enabled
Volume state : Optimal
Physical disk I/Os : Not quiesced

The status fields in the data displayed can have the following values:

Current operation

Synchronize or None

Volume status

Enabled or Disabled

Volume state

[Inactive] Optimal, Degraded, or Failed

Physical disk I/Os

Quiesced or Not quiesced

A.3.8

SETOFFLINE Command

Note:

The SETOFFLINE command is supported by the DOS,
Linux, and WinPE versions of CFGGEN only.

The SETOFFLINE command makes a physical disk in a volume offline.
A physical disk that is taken offline changes its state to Failed (FLD), but