3 installing asus pike raid card (optional) – Asus RS926-E7/RS8 User Manual

Page 45

Advertising
background image

2-23

ASUS RS920-E7/RS8; RS926-E7/RS8

• If you install two power supply units in the system, you can switch the

working behavior of the two PSUs between 1+1 jumper mode and 2+0

jumper mode.

1+1 jumper mode: If the total power consumption of the system is less

than 1400W, the system can be booted using one PSU and the PSU hot-

swap feature is supported. If the total power consumption of the system

exceeds 1400W, the maximum output power of the PSUs can reach to

2800W with PSU hot-swap feature disabled, and the system shuts down if

any of the PSUs is removed.

2+0 jumper mode: The system can be booted only when two PSUs are

installed. The maximum output power of the PSUs can reach to 2800W with

PSU hot-swap feature disabled, and the system shuts down if any of the

PSUs is removed.

• The output power varies with different input voltages. Refer to the table

below for details.

SKU

Input Voltage

Max. Output Power (Watt)

1620W 100V—140V

1100W

180V—240V

1400W

2.8.3

Installing ASUS PIKE RAID card (optional)

Follow the steps below to install an optional ASUS RAID card on your motherboard.

If you install the PIKE 2108 Series SAS RAID card, follow steps 1 and 2 to remove

the outer heatsink on RAID card.

1. Remove the two screws that secure

the heatsink bracket on the back of

the SAS RAID card.

Heatsink bracket

Advertising
This manual is related to the following products: