2 controls and indicators, 1 co-x controls and indicator – Armasight CO-X GEN 3 Ghost Night Vision Clip-On System User Manual
Page 25

25
3.2 CONTROLS AND INDICATORS
CAUTION:
DO NOT force the equipment controls past their stopping points.
3.2.1 CO-X CONTROLS AND INDICATOR
The CO-X controls and indicator are shown in Figure 3-14 and defined in Table 3-1. The ITEM NO. column
indicates the number used to identify items in Figure 3-14.
TABLE 3-1. CO-X CONTROLS AND INDICATOR
ITEM NO. CONTROL/INDICATOR
FUNCTION
1
Turn-Pull Switch Activates the CO-X, when turned to ON position.
NOTE:
Both ON and “BATTERY” end positions of the switch can only be entered
if the spindle is pulled before turning.
Actuates the battery check mode, when turned to “BATTERY” position (see
note above).
Actuates standby mode, when turned to STB.
Deactivates the CO-X, when turned to OFF.
2
Bi-color LED
Indicator
PERMANENT GREEN GLOW indicates excessive light conditions. After 10
seconds the image intensifier tube will be cut off. The CO-X turns back
again when moved away from the excessive light.
PERMANENT RED GLOW indicates usable condition of the battery.
FLASHING RED LIGHT indicates a low battery.
3
Gain Control
Knob*
Adjusts the brightness of the image.
4
Focus Knob
Focuses the objective lens. Adjusts for sharpest view of the scene. The
total focus range is covered with 0.5 turn of the knob. Directions of focus
(sharper to softer) are designated by a double arrow on the knob.
FIGURE 3-14. CO-X CONTROLS AND INDICATOR
4
3
1
2