Armasight NSMNYX14P1F6DA1 NYX-14 Pro FLAG Night Vision Monocular User Manual

Page 21

Advertising
background image

21

5. To adjust the unit for comfort, loosen the screw (B) and move the unit along the guide (D).
7. To remove the Nyx-14 PRO and turn it around, push the button down (E) and lift the unit up until it

reaches the top position. Once it reaches this position, the unit will turn off automatically.
8. Push the same button (E) to lower the Nyx-14 PRO into the proper viewing position. Turn the unit on

to proceed with your mission.
In Figure 3-3, the Nyx-14 PRO is shown in the correct position for the right eye. To readjust the Nyx-14

PRO for the left eye, reverse its positioning and reinstall it on the helmet mount bracket (see Figure 3-3).

Use the second unit rail located on the opposite side of the unit. Push the button (F) and move the unit

along the slide-rail (G) until the most comfortable position is reached.
To remove the Nyx-14 PRO from the helmet mount, loosen the screw (B), push down on the button (C),

and slide the unit out of the guide (D).

C

D

E

G

B

FIGURE 3-3. MOUNTING THE NYX-14 PRO TO A HELMET

F

A

3.1.4 MOUNTING THE NYX-14 PRO TO A WEAPON WITH A PICATINNY

MOUNT ADAPTER

NOTE

:

The Nyx-14 PRO is not a weapon sight. However, it can be used in conjunction with a collimator

dot sight or laser aiming device.

NOTE:

If mounting the Nyx-14 PRO to a weapon, Armasight recommends replacing the standard eye-

cup with an eyeguard.

To mount the Nyx-14 PRO to a weapon using the optional Picatinny mount adapter, do the following:
1. Loosen the clamping knobs (A) on the Picatinny mount adapter. Position the adapter on the weapon

rail. Adjust the adapter’s fore-and-aft positions by loosening the clamping knobs (A) and repositioning

the adapter on the weapon rail. Tighten the clamping knobs (A).
2. Align the Nyx-14 PRO and the mount adapter. Slide the unit backwards until its alignment boss is

parallel with the alignment groove (B) on the adapter. Push backwards until you hear a clicking noise

indicating that the unit is locked into the weapon mount adapter.
3. To uninstall the Nyx-14 PRO from the mount adapter, push down on the lever (C) and remove the

unit.
4. If necessary, you can change the height of the Nyx-14 PRO using an additional plate (D).

Advertising