Installation

Preinstallation

Precautions

WARNING:

• When installing in a potentially explosive environment, make sure that the motor is

properly certified.

• You must earth (ground) all electrical equipment. This applies to the pump

equipment, the driver, and any monitoring equipment. Test the earth (ground) lead to
verify that it is connected correctly.

• Motors without built-in protection must be provided with contactors and thermal

overload protection for single-phase motors, or starters with heaters for three-phase
motors. (See the nameplate on the drive unit to select properly-sized overloads.)

NOTICE:
Supervision by an authorized Xylem representative is recommended to ensure proper
installation. Failure to do so may result in equipment damage or decreased performance.

Evaluate the installation in order to determine that the Net Positive Suction Head Available
(NPSH

A

) meets or exceeds the Net Positive Suction Head Required (NPSH

R

), as stated by

the pump performance curve.

Pump location guidelines

WARNING:
Assembled units and their components are heavy. Failure to properly lift and support this
equipment can result in serious physical injury and/or equipment damage. Lift equipment
only at the specifically identified lifting points. Lifting devices such as eyebolts, slings, and
spreaders must be rated, selected, and used for the entire load being lifted.

Guideline

Explanation/comment

Keep the pump as close to the liquid source as practically

possible.
If the pump is not on a closed system, locate the pump so

that the fewest number of bends or elbows in the suction

pipe are needed.

This minimizes the friction loss and keeps the suction

piping as short as possible.

Make sure that the space around the pump is sufficient.

This facilitates ventilation, inspection, maintenance,

and service.

If you require lifting equipment such as a hoist or tackle,

make sure that there is enough space above the pump.

This makes it easier to properly use the lifting

equipment and safely remove and relocate the

components to a safe location.

Protect the unit from weather and water damage due to

rain, flooding, and freezing temperatures.

This is applicable if nothing else is specified.