Replacement guidelines, Shaft and sleeve inspection, Reassembly – Xylem AC5660 Series A-C 1500 Vertical In-Line Pump User Manual

Page 23: Replacement guidelines shaft and sleeve inspection

Advertising
background image

NOTICE:
Protect machined surfaces while you clean the parts. Failure to do so may result in
equipment damage.

Replacement guidelines

Impeller replacement

This table shows the criteria for replacing the impeller:

Impeller parts

When to replace

Impeller vanes

• When grooved deeper than 1/16 in. (1.6 mm), or
• When worn evenly more than 1/32 in. (0.8 mm)

Vane edges

When you see cracks, pitting, or corrosion damage

Gaskets, O-rings, and seatsreplacement

• Replace all gaskets and O-rings at each overhaul and disassembly.
• Inspect the seats. They must be smooth and free of physical defects.
• Replace parts if the seats are defective.

Shaft and sleeve inspection

Inspection criteria

Inspect the shaft and sleeve according to this criteria:

• Thoroughly clean the shaft and sleeve.
• Thoroughly clean the coverplate seal cavity.
• Inspect the surface for damage such as pitting, corrosion, nicks, and scratches.

Replace these parts if they are damaged.

Reassembly

Assemble the standard mechanical seal (AC-1500 and AC-1500-F)

1. Lubricate the shaft sleeve and coverplate seal cavity with soapy water.

Do not use a petroleum lubricant.

2. Install a new insert gasket.
3. Install a new seal insert and make sure that the indentation is against the insert gasket.
4. Slide a new rotating seal assembly onto the shaft sleeve.
5. Push the top of the compression ring with a screwdriver until the seal is tight against

the seal insert.

6. Install the seal spring and point the narrow end toward the seal.

Maintenance

Series A-C 1500 Installation, Operation, and Maintenance Manual

21