Assemble the single mechanical seal (ac-1500-s) – Xylem AC5660 Series A-C 1500 Vertical In-Line Pump User Manual

Page 24

Advertising
background image

1

2
3
4

5

6
7
8

9

10

11

12

13

1.

Slinger

2.

Bracket coverplate

3.

Seal assembly

4.

Impeller key

5.

Volute capscrew

6.

Impeller

7.

Impeller lockwasher

8.

Volute

9.

Impeller capscrew

10. Volute gasket

11. Impeller washer

12. Shaft sleeve

13. Shaft

Figure 2: Standard mechanical seal

Assemble the single mechanical seal (AC-1500-S)

1. Lubricate the shaft sleeve and seal cap with soapy water.

Do not use a petroleum lubricant.

2. Insert a stationary seal with an O-ring into the seal cap and slide it onto the shaft.
3. Replace the seal cap gasket.
4. Slide the rotating portion of the seal assembly onto the shaft sleeve and lock it in

place.

ID seal size

Distance between collar and impeller end of the shaft sleeve

1-1/4 in. (3.175 cm)

1-13/32 in. (3.571 cm)

1-5/8 in. (4.128 cm)

1-1/4 in. (3.175 cm)

5. Assemble the coverplate onto the bracket.
6. Tighten the capscrews according to the Capscrew torque table.
7. Attach the seal cap to the coverplate.
8. Tighten the hex nuts on the seal cap bolts according to the Capscrew torque table.

Maintenance