Assemble the double mechanical seal (ac-1500-d) – Xylem AC5660 Series A-C 1500 Vertical In-Line Pump User Manual

Page 26

Advertising
background image

1.

Seal gland

2.

Coverplate

3.

For 2 in. seal: 55/64 in. (2.813 cm)

4.

Seal locking collar

5.

O-ring

6.

Seal gland capscrew

Figure 4: 2-inch single mechanical seal

Assemble the double mechanical seal (AC-1500-D)

1. Lubricate the shaft sleeve, seal cap, and coverplate cavity with soapy water.

Do not use a petroleum lubricant.

2. Insert a stationary seal and O-ring into the seal cap.

For the 1-1/4 in. ID seal, both parts are housed in the coverplate. A seal cap gasket is
not used.

1

2

1

1.

O-rings

2.

Motor end

Figure 5: Double mechanical seal

3. Insert another stationary seal and O-ring into the coverplate.
4. Slide the seal cap onto the shaft.
5. Replace the seal cap gasket.
6. Slide the rotating portion of the seal assembly onto the shaft sleeve.
7. Assemble the coverplate onto the bracket.
8. Tighten the capscrews according to the Capscrew torque values table.
9. Attach the seal cap to the coverplate.
10. Tighten the hex nuts on the seal cap bolts according to the Capscrew torque values

table.