WARNING

Hazardous voltage
can shock, burn or
cause death.

WARNING

Hazardous
voltage

CAUTION

Hazardous Machinery

WARNING

4. Installation with pump below source of supply:

4.1. Install isolation valve in piping for inspection and
maintenance.
4.2. Do not use suction isolation valve to throttle pump!

5. Installation with pump above source of supply:

5.1. To avoid air pockets, no part of piping should be
higher than pump suction connection. Slope
piping upwards from liquid source.
5.2. All joints must be airtight.
5.3. Foot valve to be used only if necessary for priming,
or to hold prime on intermittent service.
5.4. Suction strainer open area must be at least triple
the pipe area.

6. Size of inlet from liquid source, and minimum submer-

gence over inlet, must be sufficient to prevent air
entering pump.

DISCHARGE PIPING

1. Arrangement must include a check valve located

between a gate valve and the pump. The gate valve is
for regulation of capacity, or inspection of pump or
check valve.

2. If reducer is required, place between check valve and pump.

5. Wiring and Grounding

Install, ground and wire according to
local and National Electrical Code
Requirements.
Install an all leg electrical power
disconnect switch near the pump.
Disconnect and lockout electrical
power before installing or servicing
the pump.

Electrical supply MUST match pump’s nameplate
specifications. Incorrect voltage can cause fire, damage
motor and void the warranty.
Motors without built-in protection MUST be provided
with contactors and thermal overloads for single phase
motors, or starters with heaters for three phase motors.
See motor nameplate.

• Use only copper wire to motor and ground. The ground

wire MUST be at least as large as the wire to the motor.
Wires should be color coded for ease of maintenance.

• Follow motor manufacturer’s wiring diagram on the motor

nameplate or terminal cover carefully.

FAILURE TO PERMANENTLY
GROUND THE PUMP, MOTOR AND
CONTROLS BEFORE CONNECTING
TO ELECTRICAL POWER CAN
CAUSE SHOCK, BURNS OR DEATH.

6. Rotation

DO NOT PLACE HANDS IN PUMP
WHILE CHECKING MOTOR
ROTATION. TO DO SO WILL CAUSE
SEVERE PERSONAL INJURY.

1. Pumps are right-hand rotation (Clockwise when viewed

from the driver end). Switch power on and off. Observe
shaft rotation.

2. Single-Phase: Refer to wiring diagram on motor if

rotation must be changed.

3. Three-Phase: Interchange any two power supply leads

to change rotation.

7. Operation

1. Before starting, pump must be primed (free of air and

suction pipe full of liquid) and discharge valve partially
open.

PUMPED LIQUID PROVIDES
LUBRICATION. IF PUMP IS RUN
DRY, ROTATING PARTS WILL SEIZE
AND MECHANICAL SEAL WILL BE
DAMAGED.

2. Make complete check after unit is run under operating

conditions and temperature has stabilized. Check for
expansion of piping. Check coupling alignment.

3. Do not operate at or near zero flow. Energy imparted

to the liquid is converted into heat. Liquid may flash to
vapor. Rotating parts require liquid to prevent scoring
or seizing.

8. Maintenance

FAILURE TO DISCONNECT AND
LOCKOUT ELECTRICAL POWER
BEFORE ATTEMPTING ANY
MAINTENANCE CAN CAUSE
SHOCK, BURNS OR DEATH.

FAILURE TO RELIEVE SYSTEM
PRESSURE AND DRAIN SYSTEM
BEFORE ATTEMPTING ANY
MAINTENANCE CAN CAUSE
PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH.

IF PIPING HAZARDOUS OR TOXIC
FLUIDS, SYSTEM MUST BE FLUSHED
PRIOR TO PERFORMING SERVICE.

1. Bearings are located in and are part of the motor. For

lubrication procedure, refer to manufacturer’s instructions.

FRAME-MOUNTED UNITS

• Model SFH S-group has greased for life bearings.

No regreasing is possible or necessary.

• Model SFH M-group bearing frame should be regreased

every 2,000 hours or at a three month interval, whichever
occurs first. Use a #2 lithium based grease. Fill until grease
comes out of relief fittings, or lip seals, then wipe off excess.

• Follow motor or engine and coupling manufacturer’s

lubrication instructions.

• Recheck alignment.

Hazardous fluids can

cause personal injury

or property damage.

WARNING

WARNING

Hazardous voltage
can shock, burn or
cause death.

Hazardous pressure
can cause personal
injury or property
damage.

CAUTION

Advertising