Install, ground and wire

according to local and National

Electrical Code requirements.

Install an all leg disconnect

switch near pump.

Disconnect and lockout electri-

cal power before installing or

servicing pump.

Electrical supply MUST match pump’s nameplate

specifications. Incorrect voltage can cause fire,

damage motor and voids warranty.

Motors equipped with automatic thermal protec-

tors open the motor’s electrical circuit when an

overload exists. This can cause the pump to start

unexpectedly and without warning.

• Use only stranded copper wire to motor and ground.

Wire size MUST limit the maximum voltage drop to

10% of the motor nameplate voltage, at the motor ter-

minals. Excessive voltage drop will affect performance

and void motor warranty. The ground wire must be at

least as large as the wires to the motor. Wires should be

color coded for ease of maintenance.

• Three phase motors require all leg protection with

properly sized magnetic starters and thermal overloads.

PERMANENTLY GROUND THE

PUMP, MOTOR AND CONTROLS

PER NEC OR LOCAL CODES BE-

FORE CONNECTING TO ELECTRI-

CAL POWER. FAILURE TO DO SO

CAN CAUSE SHOCK, BURNS OR

DEATH.

• Connect the electrical leads to the motor, as follows:
• Single Phase Motors – Connect the BLACK wire to the

BLACK motor wire. Connect the WHITE wire to the

WHITE motor wire. Connect the GREEN wire to the

GREEN motor wire.

• Three Phase Motors – See Figure 3.

Figure 3

NOTICE: UNIT ROTATION IS CLOCKWISE WHEN

VIEWED FROM MOTOR END.

INCORRECT ROTATION MAY CAUSE

DAMAGE TO THE PUMP AND VOIDS

WARRANTY.

• Check pump rotation by observing the motor fan or

the coupling THROUGH the coupling guard. DO

NOT confuse the flow arrows, stamped on the pump

body, with the rotation arrows on the coupling and

motor adapter. Three phase motors only – If rotation is

incorrect, have a qualified electrician interchange any

two of the three power cable leads.

DO NOT OPERATE UNIT WITH-

OUT SAFETY GUARD IN PLACE.

TO DO SO CAN CAUSE SEVERE

PERSONAL INJURY.

NOTICE: PUMP MUST BE COMPLETELY PRIMED

BEFORE OPERATION.

DO NOT OPERATE PUMP AT OR

NEAR ZERO FLOW. TO DO SO CAN

CAUSE EXTREME HEAT, DAMAGE

TO THE PUMP, INJURY OR PROP-

ERTY DAMAGE.

• After stabilizing the system at normal operating condi-

tions, check piping for correct alignments. If necessary,

adjust pipe supports.

MOTOR THERMAL PROTECTORS

CAN RESTART MOTOR UNEX-

PECTEDLY AND WITHOUT WARN-

ING, CAUSING SEVERE PERSONAL

INJURY.

• See the “ENGINEERING DATA” section in this

manual for the recommended maximum pump starts

per hour.

DISCONNECT AND LOCKOUT

ELECTRICAL POWER BEFORE

ATTEMPTING ANY MAINTE-

NANCE. FAILURE TO DO SO CAN

CAUSE SHOCK, BURNS OR DEATH.

• Unit motor requires regular lubrication maintenance.

MOTOR LUBRICATION

Recommended motor Bearing lubrication Intervals

Interval

Service Environment

1 – 2 Years

Light Duty in Clean Atmosphere

1 Year

8 – 16 hours/day – Clean, Dry Atmosphere

6 Months

12 – 24 hours/day – Moisture Present

3 Months

12 – 24 hours/day – Dirty, High Moisture

WARNING

Hazardous voltage

can shock, burn or

cause death.

WARNING

Hazardous

voltage

208-230V 3/60

460V 3/60

4
5
6

1

7

2

8

3

9

L

1

L

2

L

3

4

7

5

8

6

9

1

2

3

L

1

L

2

L

3

G

G

MOTOR LEADS

MOTOR LEADS

PO

W

ER

C

A

BL

E

LE

A

D

S

PO

W

ER

C

A

BL

E

LE

A

D

S

THREE PHASE MOTOR WIRING DIAGRAM

WARNING

Hazardous machinery

can cause personal

injury or death.

WARNING

Extreme heat can

cause personal injury

or property damage

WARNING

Hazardous

machinery

WARNING

Hazardous

voltage